No-dead zone safety light

Product Feature:
  • 1. Inquire to get latest price, goods can be finished within 2-3 working days.
  • 2. EFP series is no dead-zone safety light curtain, in accordance with EU type 4 safety standards.
  • 3. Adopting the internal MCU redundancy design, the safety light curtain has periodic self-inspection & mutual check function. Redundant dual output loop to ensure high security.

Product Details

Parameter Specification
Safety standard Type 4 (IEC 61496-1/-2), Cat.4/PLe (ISO 13849-1)
Supply voltage DC 24V ±20%
Capacity < 5W
Beam space 10mm, 20mm, 40mm
Resolution 14mm, 25mm, 45mm
Beams 10mm : 16, 20……160
20mm : 8, 10……80
40mm : 4, 6……40
Protective height S = N * Beam space + Resolution (N=Beams)
Wave length 940nm
Response time ≤ 2 * (N * 0.1 + 3)ms (N is beams)
Type of output (OSSD) PNP or NPN
Load currents 200mA (Temperature exceed 40℃ ≤ 200 mA),
Residual voltage ≤ 1V,
Voltage leakage ≤ 0.1mA.
Protective circuit Overload voltage protection, Power supply reverse polarity protection, Over current protection.
Sensing distance 0.2~5m / 0.6~12m
Anti-optical interference 10000Lux (angle > 2.5°)
Sensing method Through-beam
Synchronization Optical-syn / Wire-syn
Enclosure material Aluminum alloy
Enclosure rating IP65
Housing cross-section 33 * 38mm
Vibration resistance 10 ~ 55 Hz, amplitude 0.35 ± 0.05mm, 20 times each in X, Y, Z direction
Shock resistance 100m/s² (10G), 16ms pulse 1000 times each at X, Y, Z directions
Ambient operating temperature -10 ~ 55℃ (no freezing)
Storage temperature -30 ~ 70℃ (no freezing)
Ambient operating humidity When temperature is 20℃, humidity max. 85%
Operation time (T) 20 years (ISO 13849-1)