| Parameter | Specification |
|---|---|
| Safety standard | Type 2 (IEC 61496-1/-2), Cat.4 / PL c (ISO 13849-1) |
| Supply voltage | DC 24V ±20% |
| Capacity | < 5W |
| Beam space | 10mm, 20mm |
| Resolution | 15mm, 25mm |
| Beams |
10mm : 16, 20……160 20mm : 8, 10……80 |
| Protective height | Protection height = (N-1) * beam space, (N is beams) |
| Wave length | 940nm |
| Response time | Response Time = ((N+1) * 0.1ms) + 0.4ms (N is beams) |
| Type of output (OSSD) |
PNP or NPN Load currents ≤ 200mA, Residual voltage < 1V (except voltage drop caused by cable extension), Leakage current ≤ 1mA. |
| Protective circuit | Overload voltage protection, Power supply reverse polarity protection, Over current protection. |
| Sensing distance | 0.1~2m, 0.5~5m (Remark: If have light reflection, please let us know) |
| Anti-optical interference | 10000Lux (angle > 2.5°) |
| Sensing method | Thru-beam |
| Synchronization | Wire synchronization |
| Enclosure material | Aluminum alloy |
| Enclosure rating | IP65 |
| Housing cross-section | 28 * 30mm |
| Vibration resistance | 10 ~ 55 Hz, amplitude 0.35±0.05mm, 20 times each in X, Y, Z direction |
| Shock resistance | 100m/s² (10G), 16ms pulse 1000 times each at X, Y, Z directions |
| Ambient operating temperature | -10 ~ 55℃ (no freezing) |
| Storage temperature | -30 ~ 70℃ (no freezing) |
| Ambient operating humidity | When temperature is 20℃, humidity max. 85% |
| Operation time (T) | 20 years (ISO 13849-1) |