| Parameter | Specification |
|---|---|
| Supply voltage | DC 24V ±20% |
| Capacity | < 5W |
| Beam space | 10mm, 20mm, 40mm |
| Resolution | 20mm, 30mm, 50mm |
| Beams |
10mm : 32, 36, 40……176 20mm : 16, 18, 20……88 40mm : 8, 10, 12……44 |
| Protective height | Protective height = (N-1) * beam gap (N is beam) |
| Wave length | 940nm |
| Response time | Response time = (N * 0.1ms) + 0.4ms (N is beam) |
| Type of output (OSSD) |
PNP or NPN Load current ≤ 200mA, Residual voltage ≤ 1V (except for voltage drop caused by cable extension), Leakage current ≤ 1mA. |
| Protective circuit | Overload voltage protection, Power supply reverse polarity protection, Over current protection. |
| Sensing distance |
0.1~30m (Remark: If reflective light environment, please let us know in advance) |
| Anti-optical interference | 10000 Lux (I > 5°) |
| Sensing method | Thru-beam |
| Synchronization | Wire synchronization |
| Enclosure material | Aluminum alloy |
| Enclosure rating | IP65 |
| Housing cross-section | 99.6 * 75mm |
| Vibration resistance | 10~55Hz, double amplitude each in X, Y, Z directions for 20 times. |
| Ambient operating temperature | -10 ~ 55℃ (with no freezing) |
| Storage temperature | -30 ~ 70℃ (with no freezing) |
| Ambient operating humidity | When temperature is 20℃, humidity max 85% |