| Parameter | Specification |
|---|---|
| Standard Level | |
| Reference standard | ISO 13849-1 |
| Safety level | ISO 13849-1 Category 4 / PL e |
| Electric Parameters | |
| Power supply | DC 24V ±10% |
| Capacity | < 3W |
| Response time | < 20ms |
| Suction buffer time | < 50ms |
| Restart time | < 1s |
| Protective circuit | Overvoltage protection, reverse polarity protection |
| Input & Output | |
| Safety input | Safety switch signal |
| Input synchronization | No requirement |
| Safety output | 4 NO contacts, and 2 NC auxiliary contacts |
| B10 data |
Rated load: 400,000 times Low load: 2,000,000 times |
| Contact capacity | AC15: 5A/250V; DC13: 6A/24V |
| Electric lifetime | ≥ 100,000 times (1 NO: 5A 250VAC, Resistive load, 1s ON 9s OFF) |
| Mechanical lifetime | ≥ 10,000,000 times |
| Environment | |
| Vibration resistance | Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X, Y and Z direction |
| Impact resistance | Acceleration 10g, pulse duration 16ms, 1000 times each in X, Y and Z direction |
| Working temperature | -10℃ ~ +55℃ |
| Storage temperature | -40℃ ~ +85℃ |
| Protection level | Enclosure: IP40 / Terminal: IP20 |
| Installation / Structure | |
| Installation | 35mm DIN rail |
| Wire size | 0.2 ~ 2.5mm² |
| Size | 117 x 100.6 x 22.5 mm |