| Parameter | Specification |
|---|---|
| Standard & Safety Level | |
| Reference standard | ISO 13849-1 (Category 4/PL e) |
| Safety level | ISO 13849-1 (Category 4/PL e) |
| Electric Parameters | |
| Supply voltage | DC 24V ±10% |
| Power consumption | < 3W |
| Response time | < 20ms |
| Suction buffer time | < 100ms |
| Power-on restart time | < 1s |
| Protective circuit | Input power overvoltage protection, anti-reverse protection |
| Inputs & Outputs | |
| Safety input |
Double NPN normally closed input (ESRN type) Double PNP normally closed input (ESRP type) Dual door or emergency stop button (ESRS type) |
| Input synchronously | Unlimited (S1 is in the front of S2) |
| Safety output | 3 normally open passive contacts and 1 normally closed passive contact |
| B10 data |
Rated load: 400,000 times Low load: 2 million times |
| Contacting rating |
AC15: 5A/250V DC13: 6A/24V |
| Electric lifespan | ≥ 100,000 times (1NO: 5A 250VAC, resistive load, 1s on 9s off) |
| Mechanical lifespan | ≥ 10 million times |
| Environment & Structure | |
| Vibration resistance | Frequency 10Hz~55Hz, amplitude 0.35±0.05mm, 20 times each at X, Y, Z direction |
| Impact resistance | Acceleration 10g, pulse duration 16ms, X, Y and Z direction 1000 times each |
| Operational temperature | -25ºC ~ +60ºC |
| Storage temperature | -40ºC ~ +85ºC |
| Protection level | Shell: IP40 / Terminal: IP20 |
| Installation | 35mm DIN rail |
| Traverse size | 0.2 ~ 2.5mm² |
| Size | 117 x 100.6 x 22.5 mm |