| Parameter | Specification |
|---|---|
| Safety standard | Type 4 (IEC 61496-1/-2), Cat.4/ PLe (ISO 13849-1) |
| Supply voltage | DC 24V ±20% |
| Capacity | < 7W |
| Beam space | 10mm, 20mm |
| Resolution | 15mm, 25mm |
| Beams |
10mm : 16, 20……148 20mm : 8, 10……74 |
| Protective height | Protection height = (N-1) * beam space (N is beams) |
| Wave length | 940nm |
| Response time | ≤ 2 * (N * 0.1 + 0.3)ms (N is beams) |
| Type of output (OSSD) |
PNP or NPN Load current ≤ 500mA (Temp > 40°C ≤ 400 mA), Residual voltage ≤ 1V, Voltage leakage ≤ 0.1mA. |
| Protective circuit | Overload voltage protection, Power supply reverse polarity protection, Over current protection. |
| Sensing distance | 0.1 ~ 3m |
| Anti-optical interference | 10000Lux (angle > 2.5°) |
| Sensing method | Through-beam |
| Synchronization | Optical-syn |
| Enclosure material | Aluminum alloy |
| Enclosure rating | IP65 |
| Housing cross-section | 33 * 38mm |
| Vibration resistance | 10 Hz~55 Hz, amplitude 0.35±0.05mm, 20 times each in X, Y, Z direction |
| Ambient operating temperature | -10℃ ~ 55℃ (no freezing) |
| Storage temperature | -30℃ ~ 70℃ (no freezing) |
| Ambient operating humidity | When temperature is 20℃,humidity max. 85% |
| Operation time (T) | 20 years (ISO 13849-1) |